{"title":"Reactive Power Controllers","description":"","products":[{"product_id":"rgt-mt18-controler-putere-reactiva-18-nivele-tcr-cu-rs485-modbus","title":"RGT-MT18 - 18-level reactive power controller +TCR with RS485 ModBus","description":"\u003cp\u003e\u003cstrong\u003e18 steps + TCR Power factor controller for symmetrical\/asymmetrical networks with 5 inch touch screen and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e Reactive power control relays are designed to reduce the reactive power (inductive and capacitive) that is not used by the load and is extracted from the network. When inductive power is extracted from the network, it intervenes by removing a capacitor to an appropriate value. When capacitive power is extracted from the network, it intervenes by taking a shunt inductance to an appropriate value. In this way, it tries to reduce the inductive\/active and capacitive\/active speeds of the system. It is designed to provide a more reasonable compensation in unbalanced inductive and capacitive systems with the RGT-MT18 TCR step\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003e\u003cp\u003e Generator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Voltage, current\/voltage harmonics, inductive and capacitive alarm output\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Start, download and settlement times can be adjusted\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Remote communication with RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e A single-phase, two-phase and three-phase capacitor and a shunt reactor can be connected\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Harmonic voltage and current can be observed up to the 61st harmonic\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Total energy (import\/export) can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e The THD-V and THD-I values of each phase can be observed\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Create power analysis (20 samples 9999 min.) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Temperature alarm output\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Demand recording (active and reactive and apparent power and current demand)\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Minimum, maximum and average current and voltage values of each phase can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Current date and time\u003c\/p\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":50852479369558,"sku":"RGT-MT18","price":1380.42,"currency_code":"RON","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0011\/0422\/files\/29021cc84c53911daf6559abe27a8950.png?v=1753121082"},{"product_id":"rgt-12e-regulator-de-putere-reactiva-12-niveluri-tcr","title":"RGT-12E - 12-level reactive power regulator +TCR","description":"\u003cp\u003e\u003cstrong\u003e12-step power factor regulator + TCR with 2.9\" graphic LCD display (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e \u003cstrong\u003eThe RGT-12E\u003c\/strong\u003e \u003cstrong\u003e(TENSE)\u003c\/strong\u003e reactive power regulator is a fully automatic device for optimal switching of compensation stages.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e Digital processing of the measured values by the regulator ensures high accuracy in evaluating the effective voltage, current and power factor.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e The device setup is fully automatic - the controller itself determines the size of the individual compensation steps connected. These parameters can also be entered directly manually.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e The controller switches the compensation stages on and off so that the reactive power is regulated with a minimum number of switching operations. At the same time, the controller takes into account the uniform loading of the individual stages and preferentially switches those stages that have been de-energized for the longest time and for which the residual load is minimal. During the regulation process, the compensation stages are continuously monitored in parallel - faults and changes in values are detected, the temporarily removed stages are periodically tested and, if necessary, are re-introduced into the regulation process.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003e\u003cp\u003e Generator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Start, discharge and settlement times can be set\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e A single-phase, two-phase and three-phase capacitor and a shunt reactor can be connected\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Harmonic voltage and current can be observed up to 31 harmonics\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Total energy can be monitored (import\/export)\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e The THD-V and THD-I values of each phase can be observed\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Creating power analysis (20 samples 9999 min.) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":50852479435094,"sku":"RGT-12E","price":911.02,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0011\/0422\/files\/a1a8c8ce294759ea0cac4554bed17012.png?v=1753121086"},{"product_id":"rgt-12svc-controler-putere-reactiva-12-nivele-tcr-cu-rs485-modbus-rtu","title":"RGT-12SVC - 12-level reactive power controller +TCR with RS485 ModBus RTU","description":"\u003cp\u003e\u003cstrong\u003e12-step power factor regulator + TCR with 2.9\" graphic LCD display and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e \u003cstrong\u003eThe RGT-12SVC\u003c\/strong\u003e \u003cstrong\u003e(TENSE)\u003c\/strong\u003e reactive power regulator is a fully automatic device for optimal switching of compensation steps.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e Digital processing of the measured values by the regulator ensures high accuracy in evaluating the effective voltage, current and power factor.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e The device setup is fully automatic - the controller itself determines the size of the individual compensation steps connected. These parameters can also be entered directly manually.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e The controller switches the compensation stages on and off so that the reactive power is regulated with a minimum number of switching operations. At the same time, the controller takes into account the uniform loading of the individual stages and preferentially switches those stages that have been de-energized for the longest time and for which the residual load is minimal. During the regulation process, the compensation stages are continuously monitored in parallel - faults and changes in values are detected, the temporarily removed stages are periodically tested and, if necessary, are re-introduced into the regulation process.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003e\u003cp\u003e Generator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Start, discharge and decantation times can be set\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Remote communication with RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Single-phase, two-phase and three-phase capacitors and shunt reactors can be connected\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Harmonic voltage and current can be observed up to 31 harmonics\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Total energy (import\/export) can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e The THD-V and THD-I values of each phase can be observed\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Creating power analysis (20 samples 9999 min.) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":50852479533398,"sku":"RGT-12(SVC)","price":1085.89,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0011\/0422\/files\/ae4bcd478955332c8f4396aa87708907.png?v=1753121089"},{"product_id":"controler-de-putere-reactiva-cu-12-niveluri-cu-ecran-led","title":"Reactive power controller with 12 levels with LED screen","description":"\u003cp\u003e\u003cstrong\u003e12 steps Single-phase connection Power factor regulator for controlling the power factor in networks with balanced loads (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe reactive power control relay RGM-12S is designed to reduce inductive powers that do not utilize loads but are drawn from the grid. When inductive reactive power is drawn from the grid, it intervenes by activating the corresponding value capacitors. In this way, it tries to bring the Cos fi value to the desired level.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e7 Different power factor compensation programs\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eManual power factor compensation programs\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOnly inductive systems can be compensated\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic step measurement\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eActivation, release, and discharge times of the steps are adjustable\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHarmonic alarm values for voltage and current are adjustable\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOver and under compensation alarm values can be set\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage alarm output, harmonic voltage\/current, over and under compensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, current, and frequency values can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eActive power, reactive power, and apparent power values can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTHD-I can be monitored up to the 15th harmonic\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTHD-V can be monitored up to the 15th harmonic\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eThe cosine value can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eThe power factor value can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic fan shutdown\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eStepwise aging (in some compensation programs)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":50852479598934,"sku":"RGM-12S","price":697.65,"currency_code":"RON","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0011\/0422\/files\/0764c9ac7c5fc216c12aa893b22e4e13.webp?v=1753121093"}],"url":"https:\/\/pelek.ro\/en\/collections\/regulatoare-de-putere-reactiva.oembed","provider":"PELEK_RO","version":"1.0","type":"link"}